LANTIME M300/MRS - NTP Time Server with ultra stable Oscillator
![]()
The integrated OCXO-HQ guarantees a stable time base, a free running MRS (without any external reference like GPS or NTP) shows a maximum time error of +/- 1.6 seconds per year.
The LANTIME M300/MRS (Multi Reference Source) NTP time server uses an internal ultra stable oscillator as its stratum 0 reference. The oscillator can be disciplined on the basis of other NTP servers over the network or - f you connect an (optional) GPS antenna to it - by GPS. In totally isolated networks without any possibility of using an external NTP server or a GPS antenna, the MRS utilizes its OCXO HQ to maintain a stable time base after the time has been manually set during initial configuration. The MRS version of the LANTIME M300 comes with a high quality OXCO and is designed to act as a reliable time source in applications where no antenna can be installed. The internal OCXO-HQ can be fully disciplined by utilizing one or more remote NTP time servers. In installations where no source of time is available, the LANTIME M300 MRS can be run in a fully independent mode which requires setting the time manually during initial configuration. Its battery buffered RTC keeps the time during power outages or reboots and the intergrated oscillator maintains a stable timebase during normal operation. For more information visit the LANTIME M300/MRS MEINBERG Page!